GE’s LMS100 aeroderivative gas turbine provides a single, economical solution for the 100+ MW dispatch needs of nearly every global power segment. Offering ten-minute start times, unmatched hot day performance, load following and cycling capabilities, the LMS100 is a superior power generation solution for nearly every dispatch scenario.

Unmatched Simple Cycle Performance

Thanks to its innovative cooling system, the LMS100 can provide increased power output—no other gas turbine today has a greater efficiency.

Proven Technology - on a Larger Scale

The LMS100 comes from the CF6 family of aircraft engines, and the current fleet has over 350,000 operating hours, with over 44,000 starts.

Flexible Grid Support Without Load Reduction

Can provide power at part load as efficiently as most gas turbines at full load, and can operate with very little power loss, supporting the grid in times of high demand.
LM6000-PF+-9
LM6000-PF+-9_mobile

LMS100-PA+/PB

The LMS100 provides a single, economical solution for the dispatch needs of nearly every industry condition.

  • Leading simple-cycle efficiency (44 percent) in the industry supports grid stability and renewable energy adoption with less fuel needed. 
  • Offers two combustion technology configurations: single annular combustor with water, and dry low emissions (DLE).
  • Ten minute fast starts with cycling capability ensure total flexibility.
  • Ramps up to full power in less than 60 seconds when operating at 50% power, providing fast response to load demand variations.
  • 60 units in operation, with 350,000+ combined operating hours experience.
  • Construction includes modular “supercore”, which can be exchanged in less than four days to enhance plant availability.
Want to Learn More? 

See it in Action

Our videos can give you an in-depth look at our products, solutions, and how we work with customers just like you.

Tools & Resources

Explore our range of tools that let you choose products, keep them up and running, and enhance their power potential.

icon-links-final

Product Specifications

LMS100

Product Sheet

LMS100
Net Output (MW) 117
Net Efficiency (%) 43.1%
Net heat rate (Btu/kWH, LHV) 7,925
Net heat rate (kJ/kWh, LHV) 8,362
Exhaust temp (C) 440
Exhaust temp (F) 824
Exhaust energy (MMBtu/hr) 377
Exhaust energy  (MMkJ/hr) 398
DLE/SAC Combustor Technology SAC
Emissions – Nox (ppm @15% O2) 25

LMS100

Product Sheet

LMS100
Net Output (MW) 142
Net Efficiency (%) 52.2%
Net heat rate (Btu/kWH, LHV) 6,540
Net heat rate (kJ/kWh, LHV) 6,900
Exhaust temp (C) 440
Exhaust temp (F) 824
Exhaust energy (MMBtu/hr) 377
Exhaust energy  (MMkJ/hr) 398
DLE/SAC Combustor Technology SAC
Emissions – Nox (ppm @15% O2) 25

LMS100

Product Sheet

LMS100
Net Output (MW) 284
Net Efficiency (%) 52.4%
Net heat rate (Btu/kWH, LHV) 6,511
Net heat rate (kJ/kWh, LHV) 6,870
Exhaust temp (C) 440
Exhaust temp (F) 824
Exhaust energy (MMBtu/hr) 377
Exhaust energy  (MMkJ/hr) 398
DLE/SAC Combustor Technology SAC
Emissions – Nox (ppm @15% O2) 25

LMS100

Product Sheet

LMS100
Net Output (MW) 117
Net Efficiency (%) 44.2%
Net heat rate (Btu/kWH, LHV) 7,718
Net heat rate (kJ/kWh, LHV) 8,143
Exhaust temp (C) 432
Exhaust temp (F) 810
Exhaust energy (MMBtu/hr) 361
Exhaust energy  (MMkJ/hr) 380
DLE/SAC Combustor Technology SAC
Emissions – Nox (ppm @15% O2) 25

LMS100

Product Sheet

LMS100
Net Output (MW) 140
Net Efficiency (%) 53%
Net heat rate (Btu/kWH, LHV) 6,438
Net heat rate (kJ/kWh, LHV) 6,793
Exhaust temp (C) 432
Exhaust temp (F) 810
Exhaust energy (MMBtu/hr) 361
Exhaust energy  (MMkJ/hr) 380
DLE/SAC Combustor Technology SAC
Emissions – Nox (ppm @15% O2) 25

LMS100

Product Sheet

LMS100
Net Output (MW) 281
Net Efficiency (%) 53.2%
Net heat rate (Btu/kWH, LHV) 6,411
Net heat rate (kJ/kWh, LHV) 6,764
Exhaust temp (C) 432
Exhaust temp (F) 810
Exhaust energy (MMBtu/hr) 361
Exhaust energy  (MMkJ/hr) 380
DLE/SAC Combustor Technology SAC
Emissions – Nox (ppm @15% O2) 25