GE’s GT13E2 gas turbine offers industry-leading efficiency in the E-class segment. Two variants, the GT13E2 2012 and the GT13E2 2005, provide the flexibility you need to select the gas turbine that best fits your needs.

More Than 38% Efficiency in Simple-Cycle

The GT13E2 2012 delivers 38 percent simple-cycle efficiency and more than 55 percent combined-cycle efficiency.

High Fuel Flexibility

Superior fuel versatility enables a wide range of fuel compositions without hardware changes and best-in-class Wobbe Index and C2+ tolerance.

Two Operating Profiles

Switch online between two operating modes—one optimizing performance, the other substantially extending standard inspection intervals. This unique capability offers the potential for financial savings by allowing you to react quickly to fluctuating power demands, while keeping costs in line.
gt13e2-vertical
GT13E2 gas turbine

GT13E2 Gas Turbine(50 Hz)

Both models of the GT13E2 gas turbine, the GT13E2 2005 and GT13E2 2012, have the versatility to fit nearly every possible power plant configuration. Through upgrades to every major performance area, the GT13E2 is yet again setting higher performance standards for E-class gas turbines.

-Performance proven over more than 10 million fired hours
-Achieved a five-year availability, reliability and maintenance rating far exceeding class averages, with reliability reaching 99.1%
-150 units in commercial operation in 34 countries
-Recognized as the world’s most reliable gas turbine in its class*
-First gas turbine offering a flexible online switchable operation concept
-As much as 40% lower emissions  across the entire load range and fuel types, reaching 15 vppm at 100% load on gas and 25 vppm on oil.

*According to Operational Reliability Analysis Programme (OPAP) 

Want to Learn More? 

Tools & Resources

Explore our range of tools that let you choose products, keep them up and running, and enhance their power potential.

Product Specifications

GT13E2 2005 2012
SC Net Heat Rate (Btu/kWh, LHV) 9037 8980
SC NetHeat Rate (kJ/kWh, LHV) 9535 9474
SC Net Efficiency (%, LHV) 37.8% 38%
Comp. Pressure Ratio (X:1) 16.9 18.2
ExhaustTemperature (°F) 941 959
ExhaustTemperature (°C) 505 515
Exhaust Energy (MM Btu/hr) 1055 1155
Exhaust Energy (MM kJ/hr) 1113 1219
GT Turn-down - Minimum load  (%)  30% 30%
GT Ramp Rate - (MW/minute) 12/25 14/36/38
NOx (ppmvd) at baseload (@15% O2) 25 15
CO (ppm) at min. turn-down w/o abatement 80 25
Wobbe Variation (%)  >+/- 20% >+/- 20
Startup Time - Conventional / Peaking (min.) 25 / 15 25/15 / 10
GT13E2 2005 2012
CC Net Output (MW) 264 305
CC Net Heat Rate (Btu/kWh, LHV) 6209 6189
CC Net Heat Rate (kJ/kWh, LHV) 6551 6530
CC Net Efficiency (%, LHV) 55% 55.1%
Plant Turn-down - Minimum load  (%)  39% 39%
Ramp Rate - (MW/minute) 12 14
Startup Time (RR Hot, minutes) 30 30
Bottoming Cycle Type 2PNRH  2PNRH 
HP Throttle Press. (psia/bar) 1088/75 1088/75
HP Throttle Temp. (°F/°C) 923/495 930
Reheat Temp. (°F/°C) n/a n/a
ST Configuration (Type) STF-A200 STF-A200
GT Generator Type (Cooling) Air Air
ST Generator Type (Cooling) Air Air
GT13E2 2005 2012
CC Net Output (MW) 530 613
CC Net Heat Rate (Btu/kWh, LHV) 6186 6153
CC Net Heat Rate (kJ/kWh, LHV) 6527 6492
CC Net Efficiency (%, LHV) 55.2% 55.5%
Plant Turndown - Minimum load  (%)  19% 19%
Ramp Rate - (MW/minute) 24 28
Startup Time (RR Hot, minutes) 30 30
Bottoming Cycle Type 2PNRH  2PNRH 
HP Throttle Press. (psia/bar) 1088/75 1160/80
HP Throttle Temp. (°F/°C) 923/495 930
Reheat Temp. (°F/°C) n/a n/a
ST Configuration (Type) STF-D200 STF-D200
GT Generator Type (Cooling) Air Air
ST Generator Type (Cooling) Air Air