Customized upgrades are also available to suit individual needs.
| Value Pack |
Turbines |
Description |
| Anti-Icing Systems |
LM1600 LM2500 LM5000 LM6000 |
We offer several anti-icing systems, including bleed air systems, exhaust air heat exchanger systems and hot water systems using inlet chiller coils installed in inlet plenums. |
 |
| Electronic VSV System |
LM2500 |
The standard variable stator vane (VSV) control is an engine-mounted closed loop system that sets the VSV position based on inputs of gas generator speed and air inlet temperature. We can install an electronic VSV system that allows electronic control and monitoring of the VSV position from the engine control system, providing more accurate scheduling and adjustment of the VSV positioning. |
 |
| Fuel System Upgrades |
LM1600 LM2500 LM5000 LM6000 GG3/GG4 |
We can convert any type of fuel system including single-fuel to dual-fuel and single-fuel to single-fuel, and add fuels such as naphtha. Complete system conversions include engine hardware changes, package piping and wiring, controls software modifications, fuel pump skids and all associated hardware. |
 |
| Grid Support Operation |
LM6000 |
You can increase the utilization of LM6000 packages in peaking operation by providing grid support services that allow the gas turbine generator to act as a synchronous condenser to assist in controlling grid voltage. This is accomplished by adding a synchronous condenser clutch module between the generator and gas turbine that disengages the turbine as the turbine is normally shut down, and the generator is controlled as if it were a motor, consuming Volt-Amp Reactive power for grid stability. |
 |
| Halon to Carbon Dioxide Fire System Conversion |
LM1600 LM2500 LM5000 LM6000 |
We offer a replacement fire protection system that uses carbon dioxide instead of Halon. Halon is becoming expensive to procure and is no longer allowed in certain areas. In addition, many older fire protection systems use panels and components that are no longer manufactured, making replacement parts difficult to find. |
 |
| HMI Upgrades |
LM1600 LM2500 LM5000 |
As older model human-machine interface (HMI) systems become obsolete, replacement parts are becoming more expensive and difficult to obtain. We can upgrade HMI systems to the latest graphical-based applications in desktop or panel-mounted personal computers. These upgrades may be performed on older systems without a program change to the turbine control panel. |
 |
| Inlet Conditioning Systems |
LM1600 LM2500 LM5000 |
We offer a variety of inlet air conditioning systems that can be installed in the field, including inlet chilling and heating systems and fine mist or traditional evaporative cooling systems. You can increase engine performance by optimizing the temperature of the compressor inlet air to the gas turbine. |
 |
| Inlet Filtration Systems |
LM1600 LM2500 LM5000 LM6000 |
Undersized or improperly designed inlet filtration systems can result in restricted power output due to increase drops, higher maintenance costs and reduced availability of the unit. We can replace and upgrade existing inlet filtration systems to minimize air inlet problems. |
 |
| Liquid Fuel Treatment Systems |
LM1600 LM2500 LM5000 LM6000 GG3/GG4 Avon |
We offer centrifugal liquid fuel treatment systems for use with all LM series, Avon and GG4 gas turbines that significantly improve the quality of the fuel entering the gas turbine. |
 |
| LM5000 to LM6000 Conversion |
LM5000 |
We offer a package retrofit program to replace the LM5000 gas turbine with a new LM6000PC engine (hot end drive) within the existing package. Modifications to the existing package include a new turbine controls system, turbine mounting system, inlet bellmouth and Variable Bleed ducting redesign. |
 |
| LM6000 PA to PC Uprates |
LM6000 |
We have developed an uprate kit to incorporate the improvements developed for the production PC model into the PA model LM6000s. This kit results in an uprated PA model that exhibits the same performance as the production PC model. The LM6000PA uprate provides increased power, improved heat rate and increased reliability through the improvements made to the LPC section (including higher efficiency 0-3 vanes) and the LPT section (including higher efficiency blades and vanes). |
 |
| Lubricating Oil Chip Detectors and Oil Monitoring Systems |
LM1600 LM2500 LM5000 LM6000 |
We can install an electronic chip detector system or a lubricating oil monitoring system that continuously monitors the number of metallic and non-metallic particles in the gas turbine lubricating oil. Both systems allow early detection of potential bearing problems. |
 |
| MetalSCAN |
LM1600 LM2500 LM5000 LM6000 |
We offer a real-time oil debris monitoring system for all LM series gas turbines. MetalSCAN monitors the accumulation of ferrous material in fluid lines and initially warns the operators of any abnormal activity. When certain thresholds have been attained, MetalSCAN triggers an alarm to indicate significant wear component damage. This sensor provides early warning of bearing and gear damage, reducing the occurrences of unplanned outages. |
 |
| Remote Monitoring and Diagnostics |
LM1600 LM2500 LM5000 LM6000 |
We offer remote monitoring and diagnostic services to improve availability, reliability, operating performance and maintenance effectiveness. Factory experts monitor key parameters, providing early warning of equipment problems and avoiding expensive secondary damage. Diagnostic programs seek emerging trends and alert monitoring personnel, enabling proactive intervention to avoid forced outages and extended downtime. We are currently monitoring more than 50 LM series gas turbine installations worldwide. |
 |
| Single-Shank Upgrade Kits |
LM2500 |
We can install a single-shank upgrade kit that incorporates the improvements developed for the LM2500PE model into LM2500PC/GB machines. This kit upgrades the twin-shank engine to the single-shank configuration to yield the same performance as the production PE model, and incorporates the latest hot gas path materials and coatings |
 |
| T54 Probes |
LM2500 LM5000 |
For improved monitoring and troubleshooting capability, we offer individual readout capability for units that have only an averaging system. We also offer an individually replaceable probe system, which allows a single probe to be replaced instead of an entire quadrant. |
 |
| Vibration System Upgrades |
LM1600 LM2500 LM5000 LM6000 |
As older model vibration monitoring systems are phased out of production, maintenance and spare parts become increasingly difficult to obtain. We can upgrade older systems to the latest vibration monitoring systems, and possibly integrate the display into your Human-Machine Interface computer. |
 |
| Water Wash Systems |
LM1600 LM2500 LM5000 LM6000 |
We offer portable water wash systems that can be rolled into place and used to wash gas turbines. This portable system is especially useful for multiple-unit sites. |