Nominal Tool Diameter |
10 to 34 in |
| Number of Sensors | up to 512, depending on tool size |
| Wall Coverage | 100 percent (longitudinal weld and base material) |
| Active Range (varies with tool size) |
Up to 100 miles (160 km) at 1 m/s |
| Minimum Length of Defect | 0.98 in (25 mm) at 1 m/s for ILI tools up to 14 in 1.1 in (30 mm) at 1 m/s for ILI tools for other tools 2.2 in (60 mm) at 2 m/s for ILI tools for other tools |
| Minimum Depth of Defect | 1 mm |
| Location Accuracy - Axial - Circumferential |
± 7.8 in (± 20 cm) ± 10° |
| Markering System | Time-based marker system |